ÇѱÛÁ¦¸ñ(Korean Title) ´ÙÁß ¼¾¼­ µ¥ÀÌÅ͸¦ È°¿ëÇÑ ½Ã¾àÀå À§Çè»óȲ ½Äº° ½Ã½ºÅÛ
¿µ¹®Á¦¸ñ(English Title) Reagent Cabinet Hazard Situation Identification System Utilizing Multiple Sensor Data
ÀúÀÚ(Author) ÀÌÇöÁÖ   ÃÖÇü¿í   Á¤È¸°æ   Hyunju Lee   Hyungwook Choi   Hoekyung Jung  
¿ø¹®¼ö·Ïó(Citation) VOL 22 NO. 01 PP. 0063 ~ 0068 (2018. 01)
Çѱ۳»¿ë
(Korean Abstract)
ÃÖ±Ù ½ÇÇè½Ç¿¡¼­ ¹ß»ýÇÏ´Â ¾ÈÀü»ç°í°¡ ´Ù¾çÇÑ ÇüÅ·Π¹ß»ýÇÔ¿¡ µû¶ó ½ÇÇè½ÇÀÇ ¾ÈÀü»ç°í¸¦ ÁÙÀÏ ¼ö ÀÖ´Â ½Ã½ºÅÛÀÌ ¿ä±¸µÇ°í ÀÖ´Ù. ±âÁ¸ ½Ã½ºÅÛÀº ¿Âµµ, ½ÀµµÀÇ º¯È­¿¡ µû¶ó À§Çè»óȲÀ» ½Äº°ÇÏÁö¸¸ À§Çè»óȲÀÇ À¯ÇüÀ» ¾Ë ¼ö ¾ø°í ±â±âÀÇ µ¿ÀÛÀÌ ¼öµ¿À¸·Î ÀÌ·ç¾îÁö´Â ´ÜÁ¡ÀÌ ÀÖ´Ù. ÀÌ¿¡ º» ³í¹®¿¡¼­´Â ´ÙÁß ¼¾¼­¸¦ È°¿ëÇÏ¿© ½Ã¾àÀåÀÇ À§Çè»óȲÀ» ½Äº°ÇÏ°í ±â±â¸¦ ÀÚµ¿À¸·Î µ¿ÀÛ½ÃÅ°´Â ½Ã½ºÅÛÀ» Á¦¾ÈÇÑ´Ù. ½Ã¾àÀåÀÇ ³»ºÎ ȯ°æÀº ¼¾¼­µéÀ» ÅëÇØ ½Ç½Ã°£À¸·Î ÃøÁ¤µÇ¸ç ¼¾¼­ µ¥ÀÌÅÍ´Â À§Çè»óȲÀ» ½Äº°ÇÏ´Â °Í¿¡ È°¿ëµÈ´Ù. ¶ÇÇÑ À§Çè»óȲÀÌ ½Äº°µÇ¾úÀ» °æ¿ì ÀÌ¿¡ ¸Â´Â ±â±â¸¦ ¼±ÅÃÇÏ°í ÀÚµ¿À¸·Î µ¿ÀÛ½ÃŲ´Ù. ÀÌ¿Í °°ÀÌ ½Ã¾àÀåÀÇ À§Çè»óȲÀ» ½Äº°ÇÏ°í ±â±â¸¦ ÀÚµ¿À¸·Î µ¿ÀÛ½ÃÅ´À¸·Î½á ½Ã¾àÀå¿¡¼­ ¹ß»ýÇÏ´Â ¾ÈÀü»ç°í¸¦ ÁÙÀÏ ¼ö ÀÖÀ» °ÍÀ¸·Î »ç·áµÈ´Ù.
¿µ¹®³»¿ë
(English Abstract)
Recently, safety accidents that occur in laboratories have occurred in various forms, so that a system that can reduce safety accidents in laboratories is required. The existing system identifies the danger situation according to the change of the temperature and the humidity, but the type of the danger situation is not known and the operation of the device is manually performed. Therefore, in this paper, we propose a system that identifies the danger situation of a reagent cabinet using multiple sensors and automatically operates the device. The internal environment of the reagent cabinet is measured in real time through the sensors and the sensor data is used to identify the danger situation. Also, when a danger situation is identified, the appropriate device is selected and operated automatically. In this way, identification of the danger situation of the reagent cabinet and automatic operation of the device will reduce the safety accidents occurring in the reagent cabinet.
Å°¿öµå(Keyword) °ü¸® ½Ã½ºÅÛ   ¼¾¼­   À§Çè»óȲ ½Äº°   ÀÓº£µðµå ½Ã½ºÅÛ   Embedded   Identify the Danger Situation   Management System   Sensor  